Condo Maintenance Logbook Under Bill 16: Contents and Evidence
Bill 16 made the maintenance logbook mandatory for all divided co-ownerships in Québec. This management tool documents the condition, maintenance and work planning for the common portions and certain private portions. When properly maintained, it protects condo values, facilitates decisions by the board of directors (the board) and reduces the risk of damage. (Information current as of August 29, 2026.)
In this article, you’ll learn what the maintenance logbook must contain, who is responsible for what, and—most importantly—which evidence to keep to demonstrate compliance. You’ll also find practical advice on aligning the logbook with the contingency fund study and the maintenance logbook study.
Maintenance logbook: what Bill 16 requires and what it is for
Bill 16 amended the Civil Code of Québec to require a maintenance logbook covering all the building’s components. The purpose is to ensure structured, traceable maintenance management, so that work can be planned, common expenses budgeted appropriately and special assessments justified when necessary. See the Civil Code (see section 1070.2 and following, C.C.Q.) for the general framework.
In practical terms, the maintenance logbook:
- provides an inventory of the common portions’ components (roof, façades, parking, elevators and mechanical systems) and, where applicable, privately owned equipment subject to common maintenance (e.g., water heaters, depending on the declaration of co-ownership);
- specifies maintenance frequencies, inspections, replacement deadlines and estimated costs;
- records the history of work, contracts, warranties and damage;
- is aligned with the contingency fund study so that the budget reflects actual conditions.
The maintenance logbook study is the professional analysis that structures and updates the logbook. It is often completed alongside the contingency fund study to ensure consistency between the condition of the components and financial projections.
For regulatory reference:
- LégisQuébec – Civil Code of Québec (CCQ-1991) – divided co-ownership (see section 1070.2 and following).
- Bill 16 (S.Q. 2019, c. 28), which notably governs maintenance in co-ownerships.
Mandatory and recommended contents of the maintenance logbook
A clear, practical logbook follows a consistent structure. The following sections should be included to meet the intent of Bill 16 and industry best practices (RGCQ):
1) General information
- Identification of the syndicate of co-owners, building address, number of units and year of construction.
- References to the declaration of co-ownership, the building’s bylaws and relevant minutes.
- Contact information for the board members and manager, including their roles.
2) Component inventory
- A detailed list of the common portions’ components: building envelope, structure, roofs, balconies, common doors and windows, electrical and mechanical systems, plumbing, fire safety, elevators, parking, swimming pool and electric vehicle charging stations.
- Local particularities or previous corrective work (e.g., past infiltration or a façade rehabilitation plan).
3) Technical sheets and maintenance requirements
- For each component: description, year of installation or most recent replacement, useful life, manufacturer references, manuals and applicable RBQ instructions.
- Maintenance and inspection frequencies (preventive and regulatory), responsible parties and required qualifications (RBQ licences, engineer or architect).
4) Planning and schedule
- Schedule of periodic maintenance (monthly, seasonal, annual and multi-year).
- Projected replacement windows and cost estimates (aligned with the contingency fund study).
- Prioritization of work based on risk, safety and the available budget.
5) History and evidence
- Work register: date, supplier, RBQ permit number where applicable, cost, warranties and before-and-after photos.
- Inspection reports, tests, compliance work, notices of default and board resolutions authorizing the work.
- Damage: description, insurance claims, repairs and corrective measures.
6) Contracts and warranties
- Service contracts (elevators, HVAC and security), service levels and expiry dates.
- Builder or manufacturer warranties, recalls and maintenance instructions required to keep them valid.
7) Health, safety and compliance
- Register of regulatory requirements (e.g., alarm systems, fire extinguishers and elevator inspections), with deadlines and certificates.
- Emergency procedures and responsible parties.
Tip: keep everything in an indexed digital format, organized by keywords and component. One syndicate we assist cut its AGM preparation time in half by centralizing technical sheets, contracts and photographic evidence in a single folder linked to the agenda items.
Roles and responsibilities: board, manager and professionals
The board remains responsible for adopting, maintaining and updating the maintenance logbook. It plans priorities, approves contracts and ensures alignment with the budget, common expenses and assessments. Important decisions are reflected in the minutes and, where necessary, in amendments to the building’s bylaws.
The condo manager carries out the day-to-day work and updates: requesting quotes, following up with suppliers, recording work and filing evidence. The manager also prepares the excerpts required for the AGM and for co-owners who request them, while respecting confidentiality and the declaration of co-ownership.
Professionals (engineers, architects and technologists) conduct the maintenance logbook study and contingency fund study. They recommend maintenance, repair and replacement cycles. They sign the reports, and their recommendations support the syndicate’s financial projections.
Co-owners generally have the right to consult certain co-ownership documents, subject to the rules in the declaration of co-ownership and applicable legislation. The board may provide relevant excerpts from the logbook—for example, concerning a component affecting private portions—while protecting sensitive information.
To structure tasks, take inspiration from the areas covered by our management services: administrative and document management, and operations for preventive maintenance. See multiRent’s Administrative Management and Operations Management services page:
- Administrative management: https://www.multirent.ca/services/#gestion-administrative
- Operations management: https://www.multirent.ca/services/#gestion-des-operations
Evidence, traceability and compliance: what to keep and why
Documentation is proof. In the event of an incident, insurance claim, audit or condo sale, the syndicate’s transparency carries significant weight. The following are the main pieces of evidence to attach to the maintenance logbook:
- Detailed invoices, work orders and proof of payment;
- Signed contracts, amendments and the supplier’s certificates of insurance;
- RBQ licence number when required, and certificate of compliance;
- Professional reports (engineers and architects), tests, inspection results, recommendations and follow-up;
- Dated before-and-after photos, plans, sketches and updated technical sheets;
- Communication records: notices to co-owners and excerpts from board or AGM minutes.
These items demonstrate the syndicate’s diligence and implementation of the maintenance plan. They help the insurer assess the file and the notary prepare the transaction, particularly with the syndicate certificate and proper disclosure. For brokerage matters, the OACIQ emphasizes the importance of complete, verifiable information for buyers.
Traceability best practices:
- Version documents (v1.0, v1.1), date updates and identify the person who made the change.
- Link each intervention to a component, purchase order and board resolution.
- Archive obsolete documents without deleting them to preserve the historical record.
Implementation and updates: a simple, sustainable method
Here is a six-step process for creating or updating your maintenance logbook in accordance with Bill 16:
1) Inventory and organize
- Start with plans, the declaration of co-ownership, previous reports and equipment manuals.
- Prepare an inventory of components by common portions and privately owned equipment subject to common maintenance.
2) Collect data and evidence
- Gather contracts, warranties, photos, serial numbers, maintenance sheets and work histories.
- Identify regulatory obligations with upcoming deadlines (e.g., elevator inspections).
3) Structure the component sheets
- Create one sheet per component, with fields for frequency, responsible party, estimated cost and next action.
- Indicate the useful life and projected replacement window.
4) Plan and budget
- Prioritize based on risk, safety and financial impact; incorporate the items into the budget and contingency fund.
- Align the maintenance logbook study with the contingency fund study to avoid discrepancies.
5) Implement and monitor
- Assign responsibilities (board, manager and suppliers) and publish a shared schedule.
- Update the logbook after every intervention and at every AGM.
6) Review periodically
- Review the logbook after major inspections, damage or regulatory changes.
- Redo the contingency fund study and maintenance logbook study according to the interval provided for in the C.C.Q. (see Bill 16).
Tools and tips
- A well-structured spreadsheet works; dedicated software makes reminders and document management easier.
- Use unique codes for each component (e.g., EN-ROOF-2020) to link sheets, contracts and photos.
- Measure the maintenance plan completion rate; target >85% of planned tasks per year.
Common pitfalls to avoid
- A static logbook with no evidence or actionable schedule;
- Poor alignment with the budget and contingency fund;
- Forgetting warranties and RBQ requirements;
- Failure to provide AGM excerpts and record in the minutes decisions affecting maintenance.
For inspiration, browse other useful posts on our blog. If you’d like to compare the available support, see our packages (Standard, Advanced and Complete), adapted to the size of your syndicate.
FAQ – maintenance logbook, maintenance logbook study and contingency fund
- Is it mandatory? Yes. The C.C.Q., as amended by Bill 16, requires a maintenance logbook and maintenance logbook study for divided co-ownerships (see section 1070.2 and following, C.C.Q.).
- Who can consult the logbook? The board and manager access it for day-to-day management. Co-owners may obtain relevant excerpts, subject to the declaration of co-ownership, confidentiality rules and legislation.
- What is the difference between the maintenance logbook, maintenance logbook study and contingency fund study? The logbook is the tracking tool. The maintenance logbook study is the professional analysis that structures and updates it. The contingency fund study calculates, based on the condition of the components, the contributions required over the multi-year horizon.
Official resources
- LégisQuébec – Civil Code of Québec (CCQ-1991)
- LégisQuébec – Québec laws and regulations
- RBQ – Régie du bâtiment du Québec
- RGCQ – Regroupement des gestionnaires et copropriétaires du Québec
- OACIQ – Organisme d’autoréglementation du courtage immobilier
This article provides general information and does not constitute legal advice. Consult a lawyer or notary regarding your situation.
Do you manage a co-ownership in Québec? Discover our packages or contact us to assess your needs.